Installation aspect:
1.Installation Qualification:
The installation work must be carried out by personnel with professional qualification for the installation of explosion-proof electrical appliances to ensure that the installation process complies with explosion-proof standards and safety requirements.
2.Installation location:
It should be selected in a place with good ventilation, no corrosive gas, and no strong vibration. The installation location should be far away from fire sources, heat sources, and storage areas of flammable and explosive items.
3.Electrical Connection:
The connection of electrical circuits must be firm and comply with the installation specification of explosion-proof electrical appliances. The circuits should be protected and laid using explosion-proof dedicated metal pipes or armored cables to prevent sparks caused by circuit damage.
4.Grounding Protection:
It is necessary to ensure that the explosion-proof air conditioner is reliably grounded, and the grounding resistance should meet the requirements of relevant standards to prevent safety accidents caused by electrostatic accumulation and leakage.
5.Sealing Treatment:
The explosion-proof joint surface, inlet, and other parts of the air conditioner should undergo strict sealing treatment to prevent flammable and explosive gases from entering the interior of the air conditioner and causing an explosion.
6.Installation Acceptance:
After the installation is completed, it should be accepted by professional personnel to check whether the installation quality, electrical performance, explosion-proof performance, etc. of the air conditioner meet the requirements.
Maintenance Aspect:
1.Regular Inspection:
Regularly inspect the operating conditions of the air conditioner, including the electrical system, refrigeration system, ventilation system, etc., to ensure the normal operation of all components.
2.Cleaning and Maintenance:
Regularly clean the filter screen, heat exchanger, fan, and other components of the air conditioner to prevent the accumulation of dust and debris from affecting the performance and heat dissipation of the air conditioner. When cleaning, a damp cloth should be used to wipe to avoid generating static electricity and sparks.
3.System Maintenance:
Regularly conduct leak detection on the refrigeration system, replenish the refrigerant, and check the operating conditions of the compressor and fan to ensure the normal operation of the refrigeration system.
4.Inspection of Explosion-proof Components:
Regularly inspect the explosion-proof components of the explosion-proof air conditioner, such as the explosion-proof joint surface, seals, and explosion-proof marks, to ensure the integrity of the explosion-proof performance.
5.Maintenance Qualification:
Maintenance work must be carried out by personnel with professional qualification for the maintenance of explosion-proof electrical appliances. During maintenance, components and materials that meet the explosion-proof requirements should be used.
6.Record Archiving:
Records should be made for installation, maintenance, and repair work and archived for future reference to facilitate traceability and problem analysis.