Model | BTQ-6E |
Thermal Imagery | Thermal imaging sensor type | Vanadium Oxide Uncooled Detector |
Thermal imaging response band | 8~14μm |
Thermal imaging pixel size | 12μm |
Thermal imaging resolution | 256 × 192 |
Thermal imaging focal length & Field of view Angle | 3.3mm,50.0° × 37.3° |
Thermal imaging maximum aperture value | F1.0 |
Temperature range | -20 °C~550 °C |
Temperature Measurement Accuracy | ±2°C or ±2% of the reading (maximum) |
Noise equivalent temperature difference NETD | < 40mk(@25°C,F#=1.0) |
Spatial resolution MRAD | 4 |
Temperature anomaly function | Full screen temperature measurementExpert mode: 10 points, 10 boxes, 1 line total 21 temperature measurement rules |
Picture Calibration | Rainbow 1, iron red 2, dark brown and other 42 display modesThe distortion correction function can be enabled or disabled using Internet Explorer. After the distortion correction function is enabled, the field of view Angle of the device should be small. After the distortion correction function is enabled, the geometric distortion rate of the device should be less than or equal to 2% |
The maximum temperature measurement distance of the target (0.1×0.1 m) | 4.5m |
Maximum alarm distance for personnel (1.8m * 0.5m) | 30m |
Maximum alarm distance of vehicle (4 m *1.4 m) | 90m |
Maximum alarm distance of fire point (0.1m * 0.1m) | 18m |
Smoking detection farthest alarm distance | 4.5m |
Visible Light | Visible Light Sensor Type | 5 million starlight 1/2.7" Progressive Scan CMOS |
Visible Light Resolution | 2688 × 1520, 400 Million |
Wide Dynamic | 120dB |
Visible Focal length | 4mm,84.0° × 43.1° |
Visible light aperture value | F1.6 |
Minimum illumination | 0.0089Lux @(F1.6,AGC ON) ,0 Lux with IR |
Visible light complement function | Infrared light up to 15 meters |
Picture processing | Dual optical fusion | Support thermal imaging channel fusion visible image information, improve the thermal imaging channel image details |
Intelligent information superposition | Supports superimposed thermal imaging information in visible light channel images (only supports temperature measurement rules and temperature measurement values) |
Image correction Settings | Noise equivalent temperature difference (NETD) should be 10mk or lessThe minimum discernible temperature difference should be ≤150mkIt should be possible to filter the alarm generated by the specular reflection of the target in the monitoring screen |
System function | Action with Alarm | 1 built-in white light, 1 built-in speaker, support linkage white light alarm, support linkage sound alarm (voice can be customized) |
Perimeter defense application | Thermal imaging channel (default) : Transgression detection, area intrusion detection, entry/exit area detectionVisible light channels: Transgression detection, area intrusion detection, entry/exit area detection |
Fire monitoring application | Thermal imaging channels: smoking detection, fire point detection, temperature anomaliesVisible light channel: Smoke detection |
AI Function | The device should be able to store two open platform algorithm models, one of which can be selected to load, and the video is continuous without interruption when the algorithm is switched |
Function Setting | Can be set to trigger alarm when the number of people in the detection area is less than, equal to or greater than the preset number of the device, and can support real-time change of the number of people to capture alarm; Personnel inspection time can be set |
Video and Audio | Maximum number of preview routes | 20 Routes |
Main stream frame rate resolution | Visible light: 50Hz 25fps (2688*1520), 25fps (1920 × 1080), 25fps (1280 × 720)Visible light: 60Hz: 30fps (2688*1520),30fps (1920 × 1080), 30fps (1280 × 720)Thermal imaging: 50Hz: 25fps (1280×720P, 704×576, 640×512, 320×240) |
Substream frame rate resolution | Visible light: 50Hz: 25fps (704 × 576), 25fps (352*288)Visible light: 60Hz: 30fps (704 × 480), 30fps (352*288)Thermal imaging: 50Hz: 25fps (704×576, 640×512, 320*240) |
Video compression standard | H.265/H.264/MJPEG |
Audio compression standard | G.711/G.722.1/G.726/MP2L2/PCM |
Interface | RS485 control interface | It supports adaptive HIKVISION, PELCO-P, and PELCO-D(Addable) protocols |
Networking Protocol | IPv4/IPv6,HTTP,HTTPS,802.1x,Qos,FTP,SMTP,UPnP,SNMP,DNS,DDNS,NTP,RTSP,RTCP,RTP,TCP,UDP,IGMP,ICMP,DHCP,PPPoE,Bonjour,SFTP,SRTP |
Alarm input | Supports one DC 0~5V alarm input |
Alarm output | Support 1 normally open relay output, alarm type can be set |
Audio output | 1Route 3.5mm Impedance: 600Ω |
Audio input | 1Route3.5mm Mic in/Line in interface. Line input: 2-2.4V[p-p] |
SD card storage | Built-in Micro SD card slot, support Micro SD/SDHC/SDXC card (maximum support 256G), can support manual video/alarm video |
System Parameter | User management | Supports three levels of user rights management: administrator, operator, and common user |
Power Input | DC 12 V(±25%)or PoE (802.3af, class 3) |
Power adaptor | Packaged standard 12 VDC power adapter |
Power | 12 VDC ± 25%: 0.5 A, Max 6 W PoE (802.3af, class 3): 42.5 V to 57 V, 0.14 A to 0.22 A, Max 6.5 W |
Operating temperature and humidity | The device should work normally in the range of -50 ° C to 85 ° CTemperature Measurement Ambient temperature: -20°C to 50°C |